dem_status,station_eoi_code,station_name,component_code,component_name,component_short_name,zone_objective_code1,zone_code1,zone_name1,zone_objective_code2,zone_code2,zone_name2,measurement_code,meas_conf_group,measurement_start_date,measurement_end_date,measurement_method_type,measurement_technique_principle,measurement_equipment,integration_time_frequency,integration_time_unit,height_sampling_point,length_sampling_line,location_sampling_point,sampling_time,sampling_time_unit,calibration_frequency,calibration_unit,calibration_method,calibration_description,body_or_programme
"M","IT1180A","","9","","","","","","","","","500","500","19980602","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","320","250","ROOF","","Second","24","Hour","calibration cell","","EU EoI"
"M","IT1180A","","10","","","","","","","","","500","500","19980602","","automatic analyzer","infrared absorption","API 300","1","Hour","150","250","ROOF","","Second","3","Day","compressed gases","","EU EoI"
"M","IT1180A","","38","","","","","","","","","500","500","19980602","","automatic analyzer","chemiluminescence","API 200A","","","255","150","ROOF","","Second","24","Hour","calibration cell","","EU EoI"
"M","IT1181A","","5","","","","","","","","","500","500","20050101","","automatic analyzer","beta-absorption","Environnement MP 101 M","24","Hour","320","150","ROOF","24","Hour","3","Month","reference measurement meth.","","EU EoI"
"M","IT1181A","","8","","","","","","","","","500","500","19980602","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","320","250","ROOF","","Second","24","Hour","calibration cell","","EU EoI"
"M","IT1181A","","9","","","","","","","","","500","500","19980602","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","320","250","ROOF","","Second","24","Hour","calibration cell","","EU EoI"
"M","IT1181A","","10","","","","","","","","","500","500","19980602","","automatic analyzer","infrared absorption","API 300","1","Hour","320","200","ROOF","","Second","24","Hour","compressed gases","","EU EoI"
"M","IT1181A","","32","","","","","","","","","500","500","19980602","","automatic analyzer","chromatography","NIRA (Philips Automation) K50031","1","Hour","320","200","ROOF","15","Minute","24","Hour","compressed gases","","EU EoI"
"M","IT1181A","","38","","","","","","","","","500","500","19980602","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","320","250","ROOF","","Second","24","Hour","calibration cell","","EU EoI"
"M","IT1182A","","5","","","","","","","","","500","500","20000901","","automatic analyzer","beta-absorption","Environnement MP 101 M","2","Hour","320","150","ROOF","2","Hour","1","Month","calibration filter","","EU EoI"
"M","IT1182A","","7","","","","","","","","","500","500","19980602","","automatic analyzer","fluorescence","API400","1","Hour","320","250","ROOF","","Second","24","Hour","uv lamp (ozone generator)","","EU EoI"
"M","IT1182A","","8","","","","","","","","","500","500","19980602","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","320","250","ROOF","","Second","24","Hour","calibration cell","","EU EoI"
"M","IT1182A","","9","","","","","","","","","500","500","19980602","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","320","250","ROOF","","Second","24","Hour","calibration cell","","EU EoI"
"M","IT1182A","","38","","","","","","","","","500","500","19980602","","automatic analyzer","chemiluminescence","API 200 A","1","Hour","320","250","ROOF","","Second","24","Hour","calibration cell","","EU EoI"